Back to Top

Hi, Guest!
  • Dosimeter
  • Pendose / Pen Dose / Dosimeter Analog 200 Radiac Meter IM-264 ( Arrow-Tech W-138) ( Surveymeter/ Survey Meter/ Pendose/ Pen Dose/ Dosimeter)

Pendose / Pen Dose / Dosimeter Analog 200 Radiac Meter IM-264 ( Arrow-Tech W-138) ( Surveymeter/ Survey Meter/ Pendose/ Pen Dose/ Dosimeter)

Update Terakhir
:
31 / 03 / 2024
Min. Pembelian
:
1 Rantai

Harga

Rp. 3.750.000
A. Perdagangan Alat-Alat Proteksi Radiasi, : Surveymeter, TLD, Pendose, Shielding Pb, dll

B. Jasa Pengurusan Ijin Alat Radiasi BAPETEN, : Ijin Impor, Pengalihan, Pemanfaatan, Perpanjangan

C. Jasa lain-lain, : Kalibrasi Alat Ukur Radiasi, Sertifikasi Bebas Radiasi dan Kontaminasi, Uji kebocoran, tes Usap, Survey dan Analisis NORM dan TENORM

Detail Pendose / Pen Dose / Dosimeter Analog 200 Radiac Meter IM-264 ( Arrow-Tech W-138) ( Surveymeter/ Survey Meter/ Pendose/ Pen Dose/ Dosimeter)

The advanced PEN direct reading dosimeters are rugged, precision instruments. They are higher quality and have greater reliability than other dosimeters of this type. They measure and directly read, at any time, accumulated dose ( quantity of gamma and x-ray exposure) . PEN dosimeters are designed to satisfy military specifications for the RADIAC METER IM-264/ PD and ANSI N 13.5 and N322 requirements. A sturdy metal clip attaches the dosimeter to a pocket or any object to monitor total radiation exposure. They are hermetically sealed and immersion proof. Specifications: Exposure Range ( gamma and x-rays) Energy Dependence: ± 10% maximum change in sensitivity for x and gamma ray energies from 16 keV to 8 MeV. Electrical Leakage: In the absence of radiation, the dosimeters leakage or self discharge is less than 0.5% of full scale in 24 hours at 50° C. At 20° C dosimeters will read background radiation. After gross over exposure totaling up to 2000 R the leakage is less than 5% of full scale in 48 hours at 20° C. Thereafter, the leakage will decrease to original values. Charging Voltage: Dosimeters are capable of being charged to " zero" with 140 to 195 volts. Operational Characteristics A maximum change in sensitivity of ± 10% may occur under any probable combination of the following: A) Temperature range below -20° C ( -4° F) or above + 50° C ( 122° F) B) Greater than 50, 000 foot altitude for one month C) Relative humidity greater than 95% Highly resistant to shock and vibration. Accuracy: ± 10% of true dose for Cs-137 or Co-60 gamma. Rate Response: Dosimeters are dose rate independent. Enclosure Material: Barrel - carbon fiber-filled, high-strength, electrically-conducting plastic with metal clip. Weight: Approx. 19 grams ( 0.7 oz.) Size: PEN- 200, 500 2mSv, 5mSv Length: 11 cm ( 4.48 inches) Diameter: 1.5 cm ( 0.6 inches) PEN- 2, 5, 20 Length: 11.5 cm ( 4.52 inches) Diameter: 1.5 cm ( 0.6 inches) Options Protective sapphire lens